Solid floor refurbishment research released

Kingspan Insulation

Kingspan Insulation has published a new white paper assessing how different floor insulation specifications can impact cost and floor-to-ceiling height in home refurbishments. The report is based on research from leading consultants — Currie & Brown. It shows that Kingspan Kooltherm K103 Floorboard can provide a cost-effective option for insulating solid floors without reducing headroom.

Ground floors in many UK homes are uninsulated. By retrofitting insulation in these areas, it is possible to reduce annual energy bills by as much as £65. When choosing insulation for these refurbishment applications, it is important to look at their thermal conductivity. Insulation materials with lower thermal conductivities are more efficient and can allow a compliant U-value to be achieved with a slimmer thickness of insulation. Currie & Brown carried out a cost analysis to see how this can affect solid floor applications.

The research looked at Kingspan Kooltherm K103 Floorboard, which has the lowest thermal conductivity of any commonly used insulation (0.018 W/m·K), and expanded polystyrene (EPS) insulation with a thermal conductivity of 0.038 W/m·K. The insulation materials were compared in two refurbishment scenarios for an existing solid concrete floor with a sand and cement screed:

  1. The sand and cement screed was removed and replaced with insulation and either a 35 mm liquid screed or 65 mm sand and cement screed;
  2. The existing floor was excavated and replaced with a 100 mm concrete slab, insulation and the sand and cement or liquid screed

All constructions were designed to achieve a maximum U-value of 0.25 W/m².K – complying with the refurbishment requirements outlined within Approved Document L1B in England & Wales.

The research shows that it was considerably more cost effective to remove and replace the screed layer rather than excavating the entire slab. When adopting this approach, the Kingspan Kooltherm K103 Floorboard with liquid screed was the only construction which allowed existing headroom to be retained. This also avoids potential remedial costs relating to altering floor heights, such as raising fixtures and pipework, which were not considered within the analysis.

You can download and read the full white paper at: https://www.kingspan.com/gb/en-gb/products/insulation/kingspan-insight/maintaining-floor-to-ceiling-height-in-residential

For further information, please contact:
Tel: +44 (0) 1544 387 384
Fax: +44 (0) 1544 387 484
Email: info@kingspaninsulation.co.uk
Website: www.kingspaninsulation.co.uk
www.twitter.com/KingspanIns_UK
www.linkedin.com/company/kingspan-insulation-uk
0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *